The underfloor heating has become an element of comfort adopted by an increasing number of people, due to the aesthetic and comfort advantages offered by this system. If you are thinking of mounting such a system, but it seems difficult to mount in a wooden structure, we offer under some tips that will guarantee the success of your project.
Aspects to be taken into consideration
If the bridge you want to transform into a housing attic has a wooden floor, it is necessary to consider the following aspects:
- Wood is a flexible material, unlike the rigid structure of cement.
- The wooden floors will support a lower weight, so they will not be loaded with a wet glow or seeds.
- The wood of the floor should be protected from humidity to make sure it does not deteriorate.
What is the best choice?
We believe that the best choice for the assembly of the underfloor heating is the Pearlita system and the Vidifloor plates. You will find more details in the dry and easy article for the attic: how do you choose it and how to use it? These plates are made of a mixture of plaster and cellulose fiber, two materials that are natural elements, perfectly compatible and that offer excellent properties to the plates.
Properties offered by Vidifloor dishes
Below you will discover a list of ownership of Vidifloor plates:
- Very high resistance – Knauf cellulose fiber reinforced plasterboard is particularly resistant to large mechanical forces and pregnancies. Due to the hardness of the surface and resistance to impact, it is generally recommended for the construction of wooden or metal structures. They have the ability to take large, distributed and concentrated tasks, without other special consolidation elements, although they are thin and light. These plates support a maximum weight of 300 kg/m2.
- Simple and quick assembly and ease of positioning: allowing a significant saving time and site costs.
- THERMOCUSTIC INSISISATION – The Vidifloor plates improve acoustic and thermal performance, have provided the correct filling of wooden floors with materials that absorb the sound, which reduce the effect of the propagation of sound through the cavities. Vidifloor plates guarantee excellent insulation of the noise of the phases and are compatible with underfloor heating with thermal and electrical agent. Depending on the plan of the support layer and the desired thermal and acoustic requirements, the Vidifloor plates can be mounted on the mineral wool of pearls, basalt or polystyrene.
- The vidifloor plates of fire protection fall in class A2 of fire reaction, S1-D0. Knauf cellulose plasterboard systems have in addition to the characteristics of fire resistance in various configurations.
- Friendly with the human body: the Vidifloor plates are naturally made of toilet and cellulose fibers, they are biocompatible and help to regulate natural humidity in the rooms. Due to the natural character of the raw materials and hygroscopic properties of the plaster, the Vidifloor plates have the ability to regulate environmental humidity for better air quality.
- Allow assembly to any type of finish: carpet, linoleum, parquet or ceramic tiles. Due to the high resistance, it is possible to organize a work office without any problem. Vidifloor plates support the useless use of rollers offices.

assembly
The dry excavation must be mounted in the following configuration:
In addition to the wooden beams of the floor, a support layer is mounted (axes, for example). Immediately above the axes, a layer of paper is positioned, on which the pearlita will be poured which has the role of dry excavation. The card has a double role:
- It does not allow paper granules to flow.
- Allows vapors to circulate freely. It is important to use paper and not a PVC sheet, because in the case of the use of the PVC sheet it would act as a vapor barrier. Therefore, condensation can accumulate on the back of this sheet, which will damage the wooden structure of the floor over time. At the same time, a PVC barrier will not accidentally allow the water to evacuate the sheet. We are talking about small quantities of water here, we reach the excavation of the sheet after small domestic accidents.
- And in the case of an accumulation of accidental water at the level of the dry filling layer, the paper would help to avoid the entire surface with dry excavation. The paper allows the natural drainage of the water, the necessary repairs are reduced only to a possible restoration of the finishing of the floor diagram, without the need to dismantle the dry excavation and to heat the floor above it.
Other procedures to follow:
- The perimeter is mounted on strips of mineral wool or sponge, 10 cm wide, with the role of eliminating acoustic bridges. On the paper support layer, Pearlite is mounted with a level of leveling and with a thickness of at least 2 mm.
- A dish is mounted with a support role for underfloor heating. This can be a widening plate or a thin OSB plate.
- Above the support plate there is a layer of thin expanded polystyrene, of maximum 25 mm, in which the pipes for the pavilion are mounted. These pipes must be included in some radiant metal profiles. The role of these profiles is to distribute the heat to the Vidifloor plates evenly and efficiently. Warning: metal profiles must be perfectly on underfloor heating pipes. Usually, they are made available by the underfloor heating provider, being sized to the size of the tube. The purchase or creation of higher profiles, in which the tube «plays» or in which there are air spaces, leads to a decrease in the efficiency of the heat that takes over from the profiles and its transmission to the Vidifloor plates.
- Above the pipes and under the Vidifloor plates, a PVC sheet is mandatory with the role of the vapor barrier. The role of the PVC sheet is to protect condensation plates. The condensation accumulates over time in the channels of the underfloor heating polystyrene plates, it can occur over time after long periods of non -use of the heating of the floor, its sets and stops, due to the adjustments from a higher temperature or an accidental loss. If this condensation is not blocked, influence the void cards over time and damage them. That’s why the access of this condensation to the Vidifloor plates must be blocked with the vapor barrier. The condensation is evacuated in the form of steam (drying) when the underfloor heating is used.
Other aspects to consider
We advise you to consider the following aspects, not only above the assembly:
- In the case of underfloor heating, the execution of 10 mm dilation joints in the dry excavation, if one of the size of the room (width or length) is greater than 10 m. In addition, the structural articulations of the construction must be taken in the excavation structure.
- The maximum temperature of the thermal agent in heating below the dry vidifloor lymph is 55 ° C.
- The use of the electrical heating of the excavations or electrical heating of the tile layer is suitable only for limited extent.
- Avoid the accumulation of heat (for example, under wardrobes or rugs) for both electric heating and thermal heating. The maximum permitted temperature of the dry excavation plates is 45 ° C.
- It does not load the structure of the attic too much with a heavy finish. Opt for parquet or tiles. Find out how to mount the thin plates, suitable in the attic.
Once you have planned all the details of the assembly in the floor of the attic, we recommend that you also consider the thermal insulation of the roof. A well isolated roof will minimize heat losses, will receive more efficient heating and will help you get rid of the mold. Before the thermal isolation of the roof, make sure it does not penetrate the water. Find out what you need to know about the roof handnessability. Consider also the renewal of the balcony or terrace and you will transform the penthouse into an ideal space for playing, relaxing or working.
latest posts published
Which the market of the lease and sale contract
Modern design and energy efficiency
How many times are you updated online real estate ads?
The difference between ads for sale and rental: how to adapt the message
How to negotiate the price of a property: expert suggestions
Rental contract: for tenants and owners
The connection of the neighborhoods in Târgu Mureyond – The public transport structures with electric buses
Real estate agents SEO
How to create a safe and fun playground for children in the courtyard of your home
